Bently Nevada 330103-00-14-10-01-00 | 3300 XL 8mm Probe
$ 99.87
Description Product Overview The Bently Nevada 330103-00-14-10-01-00 is a 3300 XL 8 mm Proximity Probe. This device measures radial vibration and position in rotating machinery. Specifically, this model uses a M10 x 1 thread without armor. Its total length reaches 1.0 meter (3.3 feet), and it includes a miniature coaxial ClickLoc connector. Meanwhile, the probe tip employs Polyphenylene sulfide (PPS), while the case uses AISI 303 or 304 stainless steel. Consequently, it works reliably even in harsh industrial environments. Key Technical Data (MECE Structured) Brand & Model Brand: Bently Nevada Model: 330103-00-14-10-01-00 Series: 3300 XL Type: 8 mm Proximity Probe (Metric) Measurement Range & Performance Linear Range: 2 mm (80 mils) from 0.25 to 2.3 mm (10 to 90 mils) Output at linear range: Approximately –1 to –17 Vdc Recommended gap for radial vibration: –9 Vdc (about 1.27 mm / 50 mils) Resolution: High-resolution output per 3300 XL system spec Frequency Response: See Figures 10 & 12 for signal rolloff with long cables Electrical & Resistance Nominal DC resistance (RPROBE): 7.59 ± 0.50 Ω for 1.0m length Field wiring: 0.2 to 1.5 mm² (16 to 24 AWG) Recommended cable: 3-conductor shielded triad, tinned wiring Max field wiring length: 305 meters (1,000 feet) to Proximitor Sensor Environmental Tolerance Standard temp range: -52°C to 177°C (-62°F to 350°F) Extended tip temp: up to 218°C ( 425°F); cable up to 260°C ( 500°F) Warning: Below –34°C (–30°F) may damage pressure seal Humidity: Less than 3% ASF change after 56 days at 93% RH (IEC 68-2-3) Mechanical & Pressure Seal Probe tip material: Polyphenylene sulfide (PPS) Case material: AISI 303 or 304 stainless steel Thread size: M10x1 Max thread engagement: 15 mm Seal material: Viton® O-ring (differential pressure design) Pressure test: Not shipped pre-tested (contact custom design if needed) Interference Immunity & Safety Intrinsically safe (ia): Class I, Zone 0; AEx/Ex ia IIC T5…T1 Ga Non-incendive (nA/ec): Class I, Zone 2; AEx/Ex nA IIC T5…T1 Gc Install per drawing 141092 (zener barriers) or 140979 (non-incendive) Installation Guide Torque for standard forward mount (full case): Max 33.9 N•m (300 in•lbf), Recommended 11.2 N•m (100 in•lbf) Torque for first three threads: Max 22.6 N•m (200 in•lbf), Recommended 7.5 N•m (66 in•lbf) Max thread engagement length: 15 mm for M10x1 Use non-seizing lubricant on threads if needed Do not overtighten beyond rated torque Keep probe tip clean and free from debris Debugging & Maintenance Convenience Easy DC resistance check at probe connector (7.59 ± 0.50 Ω) Standard ClickLoc connector allows quick disconnect Field wiring up to 305 meters simplifies remote monitoring O-ring seal is replaceable (contact support) Use a gap voltage check (–9 Vdc target) for baseline setup Compatibility Notes Works with all 3300 XL Proximitor Sensors Compatible with Bently Nevada monitors and diagnostic systems For 3300 XL 11 mm Proximity Probes, check the 11 mm series here Intrinsically safe with approved barriers or galvanic isolators Non-incendive per drawing 140979 for Class I Division 2 Certifications ia marking: AEx/Ex ia IIC T5…T1 Ga (Zone 0) nA/ec marking: AEx/Ex nA IIC T5…T1 Gc (Zone 2) Class I, II, III for Groups A-G Temperature schedules for EPL Ga/Gc and Dc (see full table in manual) Packing List 1x Bently Nevada 330103-00-14-10-01-00 probe assembly 1x Miniature coaxial ClickLoc connector with protector No mounting hardware included Warranty & Shipping Warranty: 12 months from shipment date against manufacturing defects. Does not cover misuse or overtightening. Shipping carriers: FedEx, UPS, DHL (express service). For inquiries or order support: 86 158 8020 0923 (WhatsApp) Typical Applications & Diagnostic Ability Typical applications: Steam, gas, and compressor radial vibration monitoring Axial position monitoring on turbines Keyphasor reference for speed/phase measurement Pump and motor bearing wear detection Diagnostic ability: Detects shaft rub, unbalance, misalignment Provides DC gap voltage for static position analysis Works with trend analysis and predictive maintenance systems FAQ – Frequently Asked Questions 1. Can I use this probe in a high-humidity area? Yes. It passes 93% humidity test for 56 days with less than 3% scale factor change. 2. What happens if I tighten past the max torque? You may strip threads or damage the probe case. Always stay within 33.9 N•m max. 3. How do I check if my probe is working? Measure DC resistance across center to outer conductor. Expected value: 7.59 ± 0.50 Ω. 4. Does this probe work with non-Bently monitors? Only if the monitor accepts –1 to –17 Vdc output and matches 3300 XL scale factors. 5. What is the most common mistake when installing? Using too much torque on the first three threads. Use only 7.5 N•m (66 in•lbf) there. 6. Which probe should I buy for high temperature above 177°C? Choose the extended temperature range version (up to 218°C tip). This standard version works to 177°C. 7. My site is Zone 2 gas. Is this probe approved? Yes, with non-incendive connection per drawing 140979 (nA/ec marking). Selection Guide – Which 3300 XL Probe Do You Need? Need standard 8mm for most turbines? Choose 330103-00-14-10-01-00 (1m cable, ClickLoc) Need longer cable? Change Total Length Option (e.g., 20 = 2.0m) Need armor against physical damage? Select an armored version (not this model)




